THORTHEK D05
SET 50 A

DC Current Monitor & Protection Module

Monitor DC current with adjustable high and low alarm thresholds. A relay signals an external control circuit or load-disconnection device.

50 A
Included sensor rating
AH / AL
High / low current settings
1 year
Warranty as quoted

Contact sales for pricing, available quantities and delivery dates.

ONE SET. A CLEAR SCOPE.

Controller set
with a 50 A sensor

  • 011 × THORTHEK D05 controller
  • 021 × Hall-effect DC current sensor, rated 50 A
  • 03One-year product warranty under the quotation terms

Contactors, fuses or circuit breakers, power supplies, enclosures and site wiring must be specified separately for the application.

TECHNICAL SPECIFICATIONS

Key specifications
for component selection

Reference: catalogue Rev. 06 · October 2026
Confirm the supplied set details before installation

Model / Set
THORTHEK D05 / MODEL SET with a 50 A DC sensor
Controller power supply
24–35 V DC · Power consumption <3 VA
Display
Digital current display with AH and AL indicators
Alarm settings
High / low thresholds, hysteresis and alarm / reset delays
Reading rate
2 readings per second
Delay range t1 / t2
0–6,400 seconds, according to the manual in the catalogue
Alarm output
One changeover relay shared by the high and low alarms
Relay contact rating
6 A at 30 V DC / 6 A at 250 V AC, resistive load
Controller dimensions
88 × 54 × 40 mm (L × W × H)
Mounting
Rail or screw mounting · Hole centres 73 × 41 mm
Operating environment
−10 to +50 °C · Up to 85% RH · Non-corrosive conditions

The catalogue states Class 0.5 according to the manual; this does not confirm ±0.5% system accuracy. Confirm the supplied sensor's cable aperture, insulation rating, bus-voltage suitability and wiring.

APPLICATIONS

Current monitoring and alarms
for DC equipment

01

DC motors and conveyors

Track sustained increases in load current and send an alarm signal to the control system.

02

DC pumps and fans

Check whether current is above or below the defined operating range. Test the settings with the actual load.

03

DC circuits and PLCs

Use relay contacts to provide a status signal or command to external control and interlock circuits.

Operating limits to understand

50 A is the sensor rating, not the relay contact rating. The module measures current and signals an alarm. Actual load disconnection requires external equipment suited to the voltage and load.

This does not replace a DC fuse or circuit breaker and is not a high-speed short-circuit protection device. Test alarm, load disconnection, reset and supply/sensor failure behaviour before use.